High Sensitivity Cardiac Marker Ck-MB Rapid Diagnostic Test

Model NO.: CKMB-W23
Trademark: OEM
Specification: 4.0mm
Origin: China
HS Code: 3002190090
Model NO.: CKMB-W23
Trademark: OEM
Specification: 4.0mm
Origin: China
HS Code: 3002190090
High Sensitivity Cardiac Marker Ck-MB Rapid Diagnostic Test

High Sensitivity Cardiac Marker Ck-MB Rapid Diagnostic Test



INTENDED USE:
The Rapid Cardiac Markers Panel test is an immunochromatography based one step in vitro test. It is designed for qualitative determination of cardiac troponin I (cTnI), CK-MB and Myoglobin in human serum, plasma or whole blood specimens as an aid in the diagnosis of myocardial infarction.

SPECIFICATION:
1) Specimen: Whole blood/serum/plasma
2) Format: Panel

FEATURE:
1) Simple: Simply add specimen and dilution(if necessary) into sample well
2) Rapid: Results come out at 15 minutes
3) Visually interpreted: Don't need any equipment
4) Stable: More than 12 month period of validity

PACKING:
Panel: 25 tests/box, 50 tests/box

ASSAY PROCEDURE:
1) Bring all materials and specimens to room temperature.
2) Remove the test card from the sealed foil pouch.
3) Place the transfer pipette in the specimen and depress the bulb to withdraw a sample.
4) Hold the pipette in a vertical position over the sample well of the test card and deliver
7-10 drops (300-500 mL) of sample into the sample well.
Note: Please deliver sample drop by drop to ensure the best performance
5) Read the result at 15 minutes.

INTERPRETATION OF RESULTS
Positive:
If two colored bands are visible on any strip of the device within 15 minutes, the test result is positive and valid. The test result can be read as soon as a distinct colored band appears in the test area.
Note: Specimens containing very low levels of cardiac markers may develop two color bands over 15 minutes.
Negative:
If test area has no color band and the control area displays a colored band, the result is negative and valid.
Invalid result:
If a colored band does not form in the control region of any strip, the test result is invalid. The sample must be re-tested, using a new test device.


High Sensitivity Cardiac Marker Ck-MB Rapid Diagnostic Test

 

  High Sensitivity Cardiac Marker Ck-MB Rapid Diagnostic Test

High Sensitivity Cardiac Marker Ck-MB Rapid Diagnostic Test



INTENDED USE:
The Rapid Cardiac Markers Panel test is an immunochromatography based one step in vitro test. It is designed for qualitative determination of cardiac troponin I (cTnI), CK-MB and Myoglobin in human serum, plasma or whole blood specimens as an aid in the diagnosis of myocardial infarction.

SPECIFICATION:
1) Specimen: Whole blood/serum/plasma
2) Format: Panel

FEATURE:
1) Simple: Simply add specimen and dilution(if necessary) into sample well
2) Rapid: Results come out at 15 minutes
3) Visually interpreted: Don't need any equipment
4) Stable: More than 12 month period of validity

PACKING:
Panel: 25 tests/box, 50 tests/box

ASSAY PROCEDURE:
1) Bring all materials and specimens to room temperature.
2) Remove the test card from the sealed foil pouch.
3) Place the transfer pipette in the specimen and depress the bulb to withdraw a sample.
4) Hold the pipette in a vertical position over the sample well of the test card and deliver
7-10 drops (300-500 mL) of sample into the sample well.
Note: Please deliver sample drop by drop to ensure the best performance
5) Read the result at 15 minutes.

INTERPRETATION OF RESULTS
Positive:
If two colored bands are visible on any strip of the device within 15 minutes, the test result is positive and valid. The test result can be read as soon as a distinct colored band appears in the test area.
Note: Specimens containing very low levels of cardiac markers may develop two color bands over 15 minutes.
Negative:
If test area has no color band and the control area displays a colored band, the result is negative and valid.
Invalid result:
If a colored band does not form in the control region of any strip, the test result is invalid. The sample must be re-tested, using a new test device.


High Sensitivity Cardiac Marker Ck-MB Rapid Diagnostic Test

 

 

Rice is a finished product made after the process of rice cleaning, glutinous rice, rice milling, and finished product finishing. The embryo and aleurone layer of rice contain nearly 64% of rice nutrients and more than 90% of the nutrients required by the human body. It is the main food of the people of the South.
The carbohydrate in rice is mainly starch, and the edible rice has higher nutritional value.
Storage taboo
Rice should not be stored at the same time as foods with high moisture such as fish, meat, vegetables, etc., otherwise it will easily cause water to cause mildew; rice should not be stored directly on the ground, and should be placed on a dry, ventilated and clean pad; indoors should be stored with high moisture content. Otherwise, it is easy to absorb water and cause mildew; the family avoids rice stored in the kitchen because the kitchen has high temperature and high humidity, which has a great influence on the quality of rice.

Rice

Long Grain Rice,Basmati Rice,Glutinous Fragrant Rice,Long Grain Basmati Rice

Ningxia Saiwaixiang Food Co., Ltd. , http://www.nxswxfood.com