Laboratory Full-Auto Biochemistry Analyzer (AM-220)

Model NO.: AM-220
Auto: Full Auto
Trademark: AMISMED
Specification: CE
Origin: China
HS Code: 90278099
Model NO.: AM-220
Auto: Full Auto
Trademark: AMISMED
Specification: CE
Origin: China
HS Code: 90278099
Full-auto Biochemistry Analyzer AM-220 Laboratory

Laboratory Full-Auto Biochemistry Analyzer (AM-220)




280T/H (Singel/Dual Reagent) 24 hrs refrigeration(Reagent tray)
45 reagent positions, 60 sample positions, 120 reaction positions
8-step auto washing system
Precise & Reliable Sample/Reagent Filling System
Liquid level detection and volume-tracing technology: Precision filling to lessen the surface carryover
Three-dimensional probe protection technology: Collision protection, reset automatically

Bubble removing of fluid pipe technology: Vacuum degassing device effectively removes the air dissolved in fluid pipe and fill the sample and reagent precisely
Needle-plug detection technology: Intellisense whether the needle is blocked
High performance separate mixer design: Solve the problem of easy-to-condensate samples completely
Detect the sample/reagent residual volume automatically
Convenient & Effective Automatic Cleaning System

Clean the reaction cups by 8 steps and monitor the process automatically.
Pre-heating cleaning solution enhances the cleaning effect
Stable Reaction Cup Unit
Adopting air-bath technology makes the reaction cup evenly heated
Linear frequency temperature control, and temperature fluctuats within 0.1 degrees.
Thermostat device making rapid heating to meet the need of out-patient & emergency
Integrative Intelletrualized Sample needle&Reagent needle
Single needle liquid level detection design
Volume-tracking technology makes less cross-contamination among needle, sample and reagent.

Reliable Optical System
Back-spectro technology to avoid light scattering
Point source technology to achieve ultra trace analysis in order to save more reagents
Optical fiiber to transmit the signal with strong anti-jamming capability
Silicon photoelectric diode synchronous detector to ensure speed analysis
Software Platform meets customer's special requirements
Real-time whole-process reaction curve Report calculation items automatically
Self-define normal value range Print levey-jennings

Technical feature
Performance
Test Speed: 280tests/h
Test Function: Full-auto, discrete, Random access, 45 programmes simultaneously, 24hrs boot, STAT priority,
Test scope: Serum, plasma, urine
Test method: End-point, two-point, kinetic, Single/dual reagent, Single/double wavelength, linear, non-linear calibration
Items Setting: Open system, supporting the imported reagent and domestic reagent, providing arbitrary combination and optional programmes
Test Setting, single, double, combination, batch, contrast setting

Sample system
Sample tray: 60 positions for primary tubes or secondary cups
Sample volume: 2-50μ L, 0.1μ L by step, automatic sampling and deduction of sample blank during test
Sample needle: Multifunctional, liquid-detection & anti-collision protection function
Reagent System
Reagent refrigeration: 4-10° C, 24 hrs non-stop refrigeration
Reagent volume: 20-450μ L, 0.1μ L by step, fixed when set the items
Reagent needle: : Multifunctional, liquid-detection & anti-collision protection function

Reaction Center
Reaction Tray: Disc type, 6 linked cuvettes, 120 reaction positions
Reaction Volume: Mini 150μ L, Max 500μ L
Reaction Temperature: Thermostaic cuvette, 37° C, real-time display
Mixing System: Separate mixer mix the sample and reagent completly
Optical System
Optical Source: Tungsten-halogen lamp, 12V/35W, 2000hrs service time
Wavelength: 8 wavelengths selectable among 340-800nm
Absorbance: 0-4.0ABS
Resolution: 0.0001ABS
Working conditions:
Power: AC220V± 10%, 50Hz, 500w
Ambient temp: 15-30 ° C

Laboratory Full-Auto Biochemistry Analyzer (AM-220) Full-auto Biochemistry Analyzer AM-220 Laboratory

Laboratory Full-Auto Biochemistry Analyzer (AM-220)




280T/H (Singel/Dual Reagent) 24 hrs refrigeration(Reagent tray)
45 reagent positions, 60 sample positions, 120 reaction positions
8-step auto washing system
Precise & Reliable Sample/Reagent Filling System
Liquid level detection and volume-tracing technology: Precision filling to lessen the surface carryover
Three-dimensional probe protection technology: Collision protection, reset automatically

Bubble removing of fluid pipe technology: Vacuum degassing device effectively removes the air dissolved in fluid pipe and fill the sample and reagent precisely
Needle-plug detection technology: Intellisense whether the needle is blocked
High performance separate mixer design: Solve the problem of easy-to-condensate samples completely
Detect the sample/reagent residual volume automatically
Convenient & Effective Automatic Cleaning System

Clean the reaction cups by 8 steps and monitor the process automatically.
Pre-heating cleaning solution enhances the cleaning effect
Stable Reaction Cup Unit
Adopting air-bath technology makes the reaction cup evenly heated
Linear frequency temperature control, and temperature fluctuats within 0.1 degrees.
Thermostat device making rapid heating to meet the need of out-patient & emergency
Integrative Intelletrualized Sample needle&Reagent needle
Single needle liquid level detection design
Volume-tracking technology makes less cross-contamination among needle, sample and reagent.

Reliable Optical System
Back-spectro technology to avoid light scattering
Point source technology to achieve ultra trace analysis in order to save more reagents
Optical fiiber to transmit the signal with strong anti-jamming capability
Silicon photoelectric diode synchronous detector to ensure speed analysis
Software Platform meets customer's special requirements
Real-time whole-process reaction curve Report calculation items automatically
Self-define normal value range Print levey-jennings

Technical feature
Performance
Test Speed: 280tests/h
Test Function: Full-auto, discrete, Random access, 45 programmes simultaneously, 24hrs boot, STAT priority,
Test scope: Serum, plasma, urine
Test method: End-point, two-point, kinetic, Single/dual reagent, Single/double wavelength, linear, non-linear calibration
Items Setting: Open system, supporting the imported reagent and domestic reagent, providing arbitrary combination and optional programmes
Test Setting, single, double, combination, batch, contrast setting

Sample system
Sample tray: 60 positions for primary tubes or secondary cups
Sample volume: 2-50μ L, 0.1μ L by step, automatic sampling and deduction of sample blank during test
Sample needle: Multifunctional, liquid-detection & anti-collision protection function
Reagent System
Reagent refrigeration: 4-10° C, 24 hrs non-stop refrigeration
Reagent volume: 20-450μ L, 0.1μ L by step, fixed when set the items
Reagent needle: : Multifunctional, liquid-detection & anti-collision protection function

Reaction Center
Reaction Tray: Disc type, 6 linked cuvettes, 120 reaction positions
Reaction Volume: Mini 150μ L, Max 500μ L
Reaction Temperature: Thermostaic cuvette, 37° C, real-time display
Mixing System: Separate mixer mix the sample and reagent completly
Optical System
Optical Source: Tungsten-halogen lamp, 12V/35W, 2000hrs service time
Wavelength: 8 wavelengths selectable among 340-800nm
Absorbance: 0-4.0ABS